
.jpg)
Lockout/Tagout (LOTO) Compliance
Lockout/Tagout (LOTO) Compliance
ASE delivers Lockout/Tagout programs that meet OSHA 1910.147 standards. Whether you need a new system or an update to your current one, we help you implement the necessary control of hazardous energy protocols.
LOTO services include:
-
LOTO program development and written procedures
-
Equipment-specific placards and labeling
-
Authorized employee training
-
Annual audits and procedure verification
Stay compliant, reduce downtime, and ensure your team is protected during servicing and maintenance.
.jpg)
Machine Guarding Design & Implementation
Machine Guarding Design & Implementation
Machine guarding is essential to prevent contact with dangerous parts during operation. ASE offers custom safeguarding solutions based on the hierarchy of risk reduction.
We help select and install:
Fixed barrier guards
Interlocked doors
Two-hand controls
Presence sensing devices (light curtains, laser scanners)
Trapped key systems and safety mats
All solutions are designed for compliance with OSHA 1910 Subpart O and ANSI B11 standards.
.jpg)
Safety Controllers Design & Installation
Safety Controllers Design & Installation
Safety controllers are essential for monitoring and controlling machine safety functions. ASE provides turnkey safety controller solutions designed to improve protection, simplify integration, and meet regulatory requirements.
We help select and install:
2 In – 2 Out safety controllers
4 In – 4 Out safety controllers
8 In – 8 Out safety controllers
Programmable safety controllers
Dedicated power supplies and dual contactors
Quick-connect and conduit entry options for flexible installation
All systems are designed for compliance with OSHA 1910 Subpart O, ANSI B11.19, and ISO 13849 standards.
.jpg)
Electrical Safety Systems & Integration
Electrical Safety Systems & Integration
Electrical safety systems are critical for reducing risk and preventing injuries from energized machinery. ASE designs and installs reliable safety circuits and devices that protect workers and ensure compliance with current safety regulations.
We help design and implement:
Dual-channel, control-reliable safety circuits with monitoring
Gate interlocks (locking and non-locking)
Emergency stop circuits
Presence sensing devices (light curtains, area scanners)
Trapped key safety systems
Muting circuits for automated material flow
Hold-to-run control systems
And more, based on your specific application
All solutions are engineered to meet or exceed OSHA 1910 Subpart S, ANSI B11.19, and ISO 13849 safety standards.
.jpg)
E-Stop, Reset, and Request-to-Enter (RTE) Systems
E-Stop, Reset, and Request-to-Enter (RTE) Systems
Emergency controls are a core part of any machine safety system. ASE designs and installs E-Stop, Reset, and RTE circuits that provide fast, safe, and compliant machine shutdown and restart functionality.
We help design and implement:
Emergency stop (E-Stop) circuits with control reliability
Reset stations for safe machine restart
Request-to-Enter (RTE) stations for controlled access to hazardous areas
Palm buttons, pull cords, and rope switches
Reset logic to prevent accidental restart
Dual-channel circuits with fault monitoring
Location-specific placement for quick operator access
All systems are designed to comply with OSHA 1910, ANSI B11.19, ISO 13850, and NFPA 79 standards for emergency stop and reset functionality.
.jpg)
Engineering & On-Site Support
Engineering & On-Site Support
Emergency controls are a core part of any machine safety system. ASE designs and installs E-Stop, Reset, and RTE circuits that provide fast, safe, and compliant machine shutdown and restart functionality.
We help design and implement:
Emergency stop (E-Stop) circuits with control reliability
Reset stations for safe machine restart
Request-to-Enter (RTE) stations for controlled access to hazardous areas
Palm buttons, pull cords, and rope switches
Reset logic to prevent accidental restart
Dual-channel circuits with fault monitoring
Location-specific placement for quick operator access
All systems are designed to comply with OSHA 1910, ANSI B11.19, ISO 13850, and NFPA 79 standards for emergency stop and reset functionality.
